VA0V00008

Pneumatic valves - VIP (new model) - Pneumatic Coaxial Valve GAS Spring Return N.O. FKM DN 40 1'' 1/2

VIP (new model) - Pneumatic Coaxial Valve VA0V00008
Drive:GAS Spring Return N.O.
Liner:FKM
Size:DN 40 1'' 1/2
220,00 €Excl. VAT
list price
Qty
add
to cart
Article Weight [kg] Variant Spare part kit
VA0V00008 3.6 Ottone KGVV0108
GENERAL INFO
VIP (new model) - Pneumatic Coaxial Valve
  • benefits
  • features
  • dimensions
  • materials
  • diagrams and breakaway torque
  • specifications
  • accessories
  • documents

1. Internal diameter equal to the diameter of the pipe
Optimised geometry to maximise flow rate

2. Pneumatic actuator integrated in the valve
Space saving (-60%) and reduced costs compared to an automated valve

3. Piston with chemical nickel plating (20-25 micron)
Lower wear of the seals due to the increase of the surface hardness (400-550 HV)

4. Lip seals
Less wear of the seal comparing with an o-ring

Several seal materials available
Maximum compatibility with different types of fluids depending by the seals used

No external moving parts

Maximum safety
Easy mounting

Long life time granted
Lifetime 10 times longer than a ball valve with with reduced maintenance costs

100% in-house manufacturing process technology
Maximum control and accuracy in all the stages of the manufacturing process

Less Air consumption
80% less air consumption compared to an actuated valve with SR pneumatic actuator therefore less load on the compressor or the possibility of using a smaller compressor's size.

ATEX Certificate
Installation is allowed in a potential explosive environment

PED Certificate

Full compliance with European Safety Standards for Pressure Equipment

GENERAL FEATURES:
• Both Double Acting and Spring Return VIP valves (either Normally Open or Normally Closed) are available in sizes ranging from 3/8” to 2”.
• Unidirectional flow.
• GAS threaded ends as per EN 10226-1 Rp (ISO 7/1) - DIN 2999 (NPT threads on request) with control fluid connections as per NAMUR interface (optional).
• Improved fluid dynamics allow minimum pressure losses. See Flow Pressure Diagram.
• VIP valves can be used in any mounting position (horizontal, vertical or oblique).
• They can be provided with seals in NBR, FKM or EPDM:
   - NBR: suitable for air, gaseous fluids, oils, water etc.
   - FKM: perfectly suitable for most fluid. Unsuitable for steam.
   - EPDM: perfectly suitable for hot water. Unsuitable for mineral products (oils, grease, etc.).
• Possibility to check open / close valve position thanks to inductive limit switches (magnetic contact) available on request. Internal magnet needs to be requested at VIP order phase.
• Leackage rate class VI according to IEC 60534-4 (ANSI-FCI 70-2 class VI).
• According to 2014/68/EU “PED”.
• 2014/34/EU ATEX configuration to request at time of order.


CONTROL MEDIA:
• Filtered compressed air, not necessarily lubricated. At temperatures from -20°C to 0°C, use dry air.
• In case of lubricated air, seal compatible oil must be used.
• Air supply: 3 bar min.- 8.5 bar max. in Double Acting execution. 4,2 bar min.- 8.5 bar max. in Spring Return execution.

OPERATING MEDIA:
• Pressure: 10 bar max, see diagram.
• Temperature:
- NBR (also version with magnet): from -20°C (-4°F) a +80°C (176°F)
- EPDM and FKM without magnet: from -20°C (-4°F) a +150°C (302°F)
- EPDM and FKM with magnet: from  -20°C (-4°F) a +90°C (194°F)
• Vacuum tightness: 97% vacum (about 30 mbar absolut, -980 mbarg). Leackage rate <10-6 mbar·l/s (Value less than 2g of air at room temperature per year).

DIMENSIONS
DN nominal diameter
mm10152025324050
Size F
GAS/NPT3/8"1/2”3/4”
1”
1”1/4
1”1/2
2”
Bore
mm [in]
10[0.39]
15[0.59]
20[0.79]
25[0.98]
32[1.26]
40[1.57]
50[1.97]
Amm [in]
53,5[2.11]
58,95[2.32]70,75[2.79]
76[2.99]
91[3.58]
102[4.02]
114,3[4.5]
Bmm [in]
46[1.81]
51,7[2.04]
63,5[2.5]
69[2.72]
86[3.39]
96[3.78]
109[4.29]
Cmm [in]
30,5[1.2]
33,1[1.3]39[1.54]
41,5[1.63]
48[1.89]
54[2.13]59,8[2.35]
Ch.Dmm [in]
22[0.87]
27[1.06]
33[1.3]
41[1.61]50[1.97]
60[2.36]
70[2.76]
Emm [in]
28,2[1.11]
31,1[1.22]
37,5[1.48]
38,5[1.52]
45,7[1.8]
51,1[2.01]
57,1[2.25]
H
mm [in]
37[1.46]
39,6[1.56]
45,5[1.79]
48[1.89]
54,5[2.15]
60,5[2.38]
66,3[2.61]
L (GAS)mm [in]
98[3.86]
112[4.41]
135[5.31]
143[5.63]
165[6.5]
180[7.09]
205[8.07]
L (NPT)mm [in]
92,5[3.64]
106[4.17]
126[4.96]
136[5.35]
154[6.06]
171[6.73]
187[7.36]
Double acting air
dm3/ciclo
[in3/cycle]
0,024[1.46]
0,042[2.56]
0,074[4.52]0,082[5]0,15[9.15]0,218[13.3]
0,253[15.44]
Spring return air
dm3/ciclo
[in3/cycle]
0,011[0.67]
0,021[1.28]
0,034[2.07]
0,037[2.26]
0,069[4.21]0,1[6.1]
0,127[7.75]
Weight double acting “DA”
kg [lb]
0,6[1.3]0,8[1.8]
1,3[2.9]
1,7[3.6]2,8[6.2]
3,7[8.2]
5,1[11.2]
Weight spring return “SR”
kg [lb]
0,6[1.3]
0,85[1.9]
1,4[3]
1,8[4]
3[6.5]
3,9[8.6]
5,4[11.9]
Approx. switching time
ms4055607080120160

MATERIALS
Pos.Description
Q.tyMaterial
Treatment
1body
1brass CW617N
nickel plated
2sleeve
1brass CW617N
nickel plated
3seat
1brass CW617N
nickel plated
4*seat-seal
1NBR/EPDM/FKM
-
5*lip seal
2NBR/EPDM/FKM
-
6*stem O-ring
2NBR/EPDM/FKM
-
7piston
1brass CW617N
nickel plated
8*piston o-ring
1NBR/EPDM/FKM
-
9**limit switch bracket
1PA6+20% Glass
-
10**magnetic ring
1plastoferrite
-
11seat nut
1brass CW614N
nickel plated
12*sleeve O-ring
1NBR/EPDM/FKM
-
13spring
1302 S.S.
-
14**Kit Namur plate
1PA66+30% Glass, brass inserts


* Components of spare part kit
** Optional parts

Working principle
A VIP valve (patented by OMAL exclusively) is a proper automatic valve embodying both interception device (between pipe C-D) and control device (A-B).
It works thanks to the internal movement of a piston supplied with air. At the end of its stroke (a VIP valve is an ON/OFF valve), the piston presses on the seat seal or moves away from it letting the intercepted fluid flow or stopping it from flowing. As the seat is perfectly tight and the intercepted fluid pressures discharge on it, the pressure necessary to move the piston is completely independent of the fluid pressure. As a result OMAL has been able to design a light space saving and lasting valve. Its full bore and its improved internal dynamics allow minimum pressure losses, too.

Closed valve
Supplying the hole “A” with air (the hole “B” must be discharging) at the end of its stroke the piston presses on the seat seal: the valve is closed.
As in Spring Return N.C. executions the spring is in “A”, if there is no control, the piston will touch the seat seal: therefore, the preferable position is the closed one.

Transitionary phase
During the transitionary phase (the picture shows the opening transition in a Double Acting execution), one of the two holes is supplied. The piston moves axially changing the previous closed or open state. In Spring Return N.C. executions, the closing is caused by the spring (if there is no control). In Spring Return N.O. executions, the opening is caused by the spring (if there is no control). Both opening and closing transitionary phases last less than a second.

Opened valve
Supplying the hole “B” with air (the hole “A” must be discharging) at the end of its stroke the piston is at maximum distance from the seat seal: the valve is open.
As in Spring Return N.O. executions the spring is in “B”, if there is no control, the piston will be away from the seat seal: therefore, the preferable position is the open one.

NAMUR SOLENOID VALVE
Solenoid valve
ER8188A2
ER8188A4
ER8188A5
ER8188C2
ER8188C4
Voltage
24V AC
115V AC
230V AC
24V DC
110V DC

MICRO SOLENOID VALVE
Solenoid valve
EP415024
EP415110
EP415220
EP412012
EP412024
Voltage24V AC
115V AC
230V AC
12V DC
24V DC

Solenoid valve 5/2 as per NAMUR
• This solenoid valve is designed for the selection of the functions 5/2 and 3/2, which is realized by using wing the appropriate plate.
• Full-working input power - D.C.: 2,5 W.
• Full-working input power - A.C.: 2 W.
• Supply voltage tolerances: +/- 10%.
• Coil insulation: F-class.
• Protection with connector: IP65.
• Electric connection: PG 9.
• Pneumatic connections: inlet 1/4”; outlet 1/4” ISO 228.
• Max. pressure: 10 bar.
• Operating media temperature: from -10°C to +80°C.
• Ambient temperature: from -10°C to +50°C.

Micro solenoid valve
• This solenoid valve is connected by a joint which fits directly to the actuator air intake, without other fittings or fixing screws.
• 3/2 solenoid valve, with solenoid available in the following voltages: 24-110-220V AC; 12-24V DC.
• Starting input power - A.C.: 9 VA.
• Full-working input power - D.C.: 5 W.
• Full-working input power - A.C.: 6 VA.
• Supply voltage tolerances: +/- 10%.
• Copper wire insulation: H-class.
• Coil insulation: F-class.
• Protection with connector: IP65.
• Electric connection: PG 9 any orientation acceptable 360°.
• Pneumatic connections:1/8” ISO 228 any orientation acceptable 360°.
• Max. pressure: 10 bar.
• Operating media temperature: from -10°C to +50°C .
• Ambient temperature: from -10°C to +50°C.
• ø Bore 1,3 mm.

LIMIT SWITCH

VIP can be provided with inductive limit switch (magnetic contact) and signal LED. Limit switches can be easily mounted in the integrated slots and fixed with a screw. Since the magnets are situated inside the valve, they must be mounted while assembling the VIP and not afterwards. For this reason, in case needed, magnet must be requested at VIP order phase.
The maximum fluid temperature must be lower than the maximum temperature supported by the limit switch.

LIMIT SWITCH TECHNICAL DATA
Electrical design

REED (PNP/NPN)
REED (PNP)
HALL (PNP)
HALL (PNP)
Type of contact

N.O.
N.O.
N.O.
N.O.
Operating voltage
V
5-120 AC/DC
5-50 AC/DC
10-30 DC
10-30 DC
Permanent current rating of switching output AC
mA100350--
Permanent current rating of switching output DC
mA100500100100
Degree of protection

IP 67IP 67IP 69KIP 67
Ambient temperature
°C-25/70
-25/+70
-25/+85
-25/+60
°F-13÷158
-13 ÷ +158
-13/185
-13/+140
Wire number

2333
Wire length
m220,320,320,3
ft6,566,5616,5616,561
Mounting type

DirectDirect
M12Direct
M12Direct
M12
Atex category

---II 3D Ex tc IIIC T125°C Dc C
Certifications

CE/UKCA/UL/EAC/CCC
CE/UKCA/UL/EAC/CCC
CE/UKCA/UL/EAC
CE/UKCA/EAC
Code

FM7B7200
FM7B9200
FM7B9112
FM7C3200
FM7C3112
FM7A3200
FM7A3112
Material

PA / Inox

Limit switch wiring

NAMUR PLATE ADAPTER

VIP
DN10 ÷ DN50
KBNJ0001


The maximum fluid temperature must be
lower than the maximum temperature
supported by the solenoid valve.

disponibilita
SHIPPING WITHIN
48 HOURS

spedizioni
FAST DELIVERY
FROM € 7,00